PLEASE NOTE:
This page
CANNOT be electronically submitted and must be PRINTED and then FAXED. Print this document -- the "TEMA Data Sheet" (expect 2-3 printed pages) and, after filling it out, fax it to Doyle & Roth at 212-248-4780.


INSTRUCTIONS:
  • The items marked with an "(A)" are required to thermally rate and quote a heat exchanger.
  • Those items marked with a "(B)" denote the thermal properties which are needed if the process fluid is not in our data bank. If the process fluid is condensing and not in our data bank, a condensing curve is also required.
  • Those items marked with a "(C)" are required for mechanical quotation for predesigned equipment.

Your Company Name

Date

Telephone

Fax

Contact Name

End User

Address

.

Installation Location

Equipment Tag No.

Service of Unit

(A) Type

(A) Horiz/Vert

Size

Connected In

Parallel

Series

Sq. Ft. Surf./Unit (Gross)(Eff.)

Shell/Unit

Sq.Ft./Shell (Gross)(Eff.)

Performance of One Unit

Fluid Allocation

(In) Shell Side (Out)

(In) Tube Side (Out)

(A) Fluid Circulated

.

.

(A) Fluid Quantity Total - Lb/Hr

.

.

(A) Vapor (In/Out) - Lb/Hr



(A) Liquid - Lb/Hr

.

.

.

.

(A) Steam - Lb/Hr

.

.

.

.

(A) Water - Lb/Hr

.

.

.

.

(A) Non-Condensable - Lb/Hr

.

.

.

.

(A) Temperature (In/Out) °F





(B) Density





(B) Viscosity, Liquid Cp





(B) Molecular Weight, Vapor





(B) Mol. Wt., Noncondensable





(B) Specific Heat - BTU/LB°F





(B) Thermal Cond.
BTU Ft/Hr Sq.Ft. °F





(B) Latent Heat - BTU/LB °F





(A) Operating Pressure - PSIG





Velocity - Ft/Sec





(A) Press.Drop Allow/Calc. PSI





Fouling Resistance (Min.)





Heat Exchanged BTU/Hr

MTD Corrected °F

Transfer Rate, BTU Hr Sq.Ft. °F -Service

Clean

Fax to Doyle & Roth at 212-248-4780.

Construction of One Shell

Sketch (Bundle/Nozzle Orient'n)


.

Shell Side

Tube Side

.

(C)(A) Design/Test Pressure, PSIG



(C)(A) Design Temperature, °F



(C) No. Passes Per Shell



(C) Corrosion Allowance, In.



(C)
Connections
Size & Rating

In



Out



Intermediate



(C) Tube No.

O.D.

Thk. (Min/Avg)

Length

Pitch

30 / 60 / 90 / 45

(C) Tube Type

Material

Shell

I.D.

O.D.

Shell Cover (Integ.) (Remov.)

(C) Channel or Bonnet

Channel Cover

Tube Sheet - Stationary

Tube Sheet - Floating

Floating Head Cover

Impingement Protection

pv2

Baffles (Cross)

Type

% Cut

Spacing

c/c

Baffles (Long)

Seal Type

Supports - Tube

U-Bend

Type

Bypass Seal Arrangement

Tube/Tubesheet Joint

Gaskets

Expansion Joint

Type

Code Requirements

ASME VIII
Div 1

Code Stamp Yes/No

(A)TEMA Class

Weights/Shell - Shipping

Filled With Water

Bundle

Remarks:

(C) (A) Materials of Construction